ADM

Landing call module

The ADM is the interface between the landing call panel and FST controller. The following landing call modules are available:

ADM-S & ADM-D

The ADM-S and ADM-D landing call modules form the interface between the landing call panel and FST-2 controller. The ADM-S or ADM-D is connected to the FST-2 via the LON bus. The ADM-S or ADM-D is typically installed on each floor.

Both modules are based on the same hardware and are available in the following software versions:

  • ADM-S: ADM Single for individual lifts
  • ADM-D: ADM Double for group lifts

 

The ADM-S or ADM-D are either installed and pre-wired in the landing call panel or delivered loose (to be installed in the shaft).

ADM-3

The ADM-3 landing call module forms the interface between the landing call panel and FST controller. It is connected to the FST via the LON bus. The ADM-3 is typically installed on each floor. The ADM-3 landing call module combines the ADM-S and ADM-D modules.

The features of the hardware are:

  • Recessed yellow service LED
  • Service pin as contact surface
  • Recessed red LED between X1 and X2
  • Recessed green LED between X1 and X2
  • 250 mA fine-wire fuse between X1 and X2
  • Additional connections X3.0 and X3.21

For a greater range of functions, the module is also in

ADM-XF

The ADM-XF controls the connected landing call panels via separate ribbon cable. The ADM-XF is installed once in the control cabinet and, from there, controls the buttons and departure arrows for up to 14 floors.
The ADM-XF is suitable only for individual lifts.

ADM-XK

The ADM-XK controls the connected landing call panels via the control cables connected to X1. The ADM-XK is installed once in the control cabinet and, from there, controls the buttons and departure arrows for up to 14 floors (2-button).
The ADM-XK is suitable only for individual lifts.

Technical data

 

ADM-3

ADM-F

ADM-XK

Supply voltage 24 V DC ±10% 24 V DC ±10% 24 V DC ±10%
Typical power consumption 50 mA 50 mA 50 mA
Outputs Short circuit-proof Short circuit-proof Short circuit-proof
Length x height x depth 50 x 54 x 20 mm 50 x 54 x 20 mm 72 x 144 x 15 mm
Temperature range: Storage & transport / operation -20 – +70 °C / ±0 – +60 °C -20 – +70 °C / ±0 – +60 °C -20 – +70 °C / ±0 – +60 °C
Relative humidity: Storage & transport / operation
(non-condensing)
+5 – +95 % / +15 – +85 % +5 – +95 % / +15 – +85 % +5 – +95 % / +15 – +85 %
{{::}}